Solute dissolves; solvent dilutes or extracts.
โ Must-know
A fastened cotton lab coat, safety goggles for chemistry practicals, trousers covering the legs, closed-toe shoes, and tied-back long hair are required or recommended laboratory attire, while contact lenses are strongly discouraged and tights and long skirts are prohibited.
Eating, drinking, smoking, using a phone, and mouth pipetting are prohibited in the practical workroom, and hands must be washed at the end of the session and immediately after contamination.
During a session, containers must remain identified, solutions must be poured into a beaker before pipetting, bottles must be closed immediately after use, and equipment must be handled carefully.
After a session, solutions must not be returned to original bottles, waste must be disposed of appropriately, unknown solutions must not remain on benches, equipment must be cleaned and reset, and the workbench must be checked by a supervisor before leaving.
Further detail
๐ Before a session, benches and fume hoods must be clear, both exits must remain accessible and unlocked, and all bottles must be labelled.
Before: clear and label; during: identify and protect; after: dispose and clean.
โ Must-know
๐ Beakers, Erlenmeyer flasks, and graduated cylinders are low-precision glassware used for approximate volumes, whereas volumetric flasks, graduated pipettes, volumetric pipettes, and burettes measure volumes precisely.
๐ During volume reading, the bottom of the meniscus must align with the graduation mark while the eye is level with the mark to avoid parallax.
Further detail
A graduated pipette withdraws precise variable volumes from 0.1 to 50 mL.
A two-mark volumetric pipette withdraws a precise fixed volume from 1 to 50 mL, whereas the listed available sizes range from 1 to 100 mL.
๐ Glassware and small laboratory materials must be labelled with the relevant identity, concentration, sample, medium, temperature, time, date, or operator information required by the procedure.
Beakers approximate; volumetric glassware measures precisely.
โ Must-know
๐ Container rinsing consists of: removing marker annotations, collecting remaining liquid, rinsing several times with tap water, lightly rinsing with distilled water, placing the container upside down or on a drying rack
๐ A used pipette is rinsed by:
Further detail
๐ Alcohol may accelerate drying only after proper water washing because it can dehydrate residues and cause red blood cells to adhere irreversibly to the pipette.
Remove labels, collect residues, rinse with tap water, finish with distilled water.
๐ A pipette must never be used by mouth or left hanging from the pipette filler, and it must be held either with the upper hand and filler or with the lower hand between the index and middle fingers.
A removes air, S suctions, E expels.
โ Must-know
๐ The micropipette with the largest capacity that can deliver the required volume should be selected; for 100 ยตL, the P100 is chosen over the P200 and P1000 for greater precision.
Further detail
๐ During sterile handling, only the sterile tip may enter the tube, while the tip cone must remain outside and be wiped with an alcohol-soaked wipe before and after the procedure.
Choose, aspirate, dispense, eject, return.
๐ Formula โ Conservation of solute in a dilution is expressed as .
๐ Formula โ The dilution factor is expressed as .
๐ Preparing a dilution consists of:
A calibration series generally includes a blank at zero concentration and at least five calibration points distributed across the studied concentration range.
Conserved solute with increased volume causes lower concentration.
๐ Formula โ Absorbance is calculated as .
๐ Plastic cuvettes are used for non-corrosive solutions in the visible range from 400 nm to 800 nm, glass cuvettes are used for corrosive solutions and certain organic solvents in the visible range, and quartz cuvettes are used in the ultraviolet range from 200 nm to 400 nm.
๐ In absorbance mode,:
A calibration curve of absorbance versus concentration is a straight line passing through the origin, and the concentration of an unknown can be determined from its measured absorbance.
Choose cuvette, set wavelength, blank, measure, recheck blank.
โ Must-know
๐ Microscope focusing consists of:
Total magnification is calculated by multiplying the eyepiece value by the objective value.
๐ The 100x objective is used only with immersion oil for very small structures, and after oil is applied the observer must not switch back to a lower-power objective.
Further detail
Low power, coarse focus, fine focus, higher power, immersion oil.
โ Must-know
๐ A graph title must express the result variable as a function of the studied variable, corresponding mathematically to .
๐ Formula โ A linear regression line is written as , where is the slope and is the intercept, and the line passes through the centroid of the points.
๐ A correlation coefficient r close to 1 or -1 indicates that a line is a suitable model, whereas a value close to 0 indicates a more circular scatter for which determining a line is not justified.
Further detail
๐ Formula โ The slope between two points is calculated as .
Measured pairs produce a fitted line whose slope and correlation assess the relationship.
Laboratory Glassware Precision
| Equipment | Main use | Precision |
|---|---|---|
| Beaker | Holding liquid or intermediate sampling | Low |
| Erlenmeyer flask | Collecting liquid or containing potentially violent reactions | Low |
| Graduated cylinder | Approximate volume measurement | Low |
| Volumetric flask | Preparing a precise final volume | High |
| Graduated or volumetric pipette | Transferring variable or fixed precise volumes | High |
| Burette | Dropwise addition of a reagent | High |
Test your knowledge on Laboratory Techniques and Safety with 11 multiple-choice questions with detailed corrections.
1. What role does a solvent play in a solution?
2. What is distilled water primarily characterized by?
Memorize the key concepts of Laboratory Techniques and Safety with 14 interactive flashcards.
What is demineralized or ultrapure water?
Water with dissolved minerals and ions removed, supplied in 5L or 10L containers.
Distilled water: process label
Boiling then condensation removes impurities
How is distilled water obtained?
By boiling followed by condensation removing most minerals, impurities, and microorganisms.